Description:
This series of fan component by the collector, chassis, impeller and
transmission parts. The chassis is welded by Q235 steel plate, and with
16Mn wear liner welded inside, also use the same wear liner in volute,to improve the wear ability and life. Large size fan casing back plate with fixed on the basis of steel brace. Chassis and cover plate and collector are connected with bolt. Removable top 1/4 of the chassis,can bring up the impeller after apart, Chassis bottom side have an ash door, easy to maintain and check
M5-29 type dust fan is dust fan is independently developed by our
company, which have high static pressure, wear resistance, efficient
wide area,a new energy-saving product instead of M9一27、M7-29、M9一26 type
blower.
This series of fan suit for 50MW-300MW transport boiler coal powder for
power plant, medium humidity should not exceed 250 °C , dustiness should
not exceed 80g / m ', also applies to transport other non-corrosive
gases.